The evaluation of quality for drinking water produced in softening plant of Libyan Iron and Steel Company in Misurata were studied at four sites in distribution network form January to June 2013. Some physicochemical parameters were measured such as, Temperature, EC, pH, TH, Ca-H, Cl-1 , SO4 -2 ,TA ,HCO3 -1 and Fe. These parameters used in indices calculation in this study. Fives indices such as Langlier Saturated Index (LSI), Ryzer Stability Index (RSI), Puckorius Scaling Index (PSI), Larson-Skold Index (LI) and Aggressive Index (AI) are used to know the state of equilibrium in water inside the network. LSI ,RSI ,PSI ,LI and AI, calculations assigned that water was not able to form precipitate, which might be a cause of corrosion inside the pipes
[1]. E.W. Rice., R.B.Baird., L.S.Clesceri. and A.D.Eaton., American Public Health Association, American Water Association , Water Enviorment Fedration, Standard methods for examination of water and wastewater, 20th ed.,Washington Dc ; American Public Health Association; 1998, 1281.
[2]. I.A. Alam. and M.Sadiq. Metal contamination of drinking water from corrosion of distribution pipes. Envi. Poll. 1989 ,57(2) , 167.
[3]. J.A.Salvato., N.L.Nemerow. and F.J.Agowdy., Environmental Engineering., 5th ed.,New Jersey,John Wiley and Sons Inc.,2009, 1049.
[4]. Guidlines for drinking water quality, World Health Organization(WHO),Geneva,2008.
[5]. A.Joseph., P.E.Salvato., Dee. N.L.Nemerow and F.J.Agrody., Enviornmental Engineering, John Wiley & Sons,Inc.,2003.
[6]. F.Kemmer., The Nalco Water Handbook, 2nd ed.,McGram-Hill Inc.,New York,1988,p.20.
[7]. J.O.Salvato. and P.Dee.,Enviornmental Engineering & Sanitation, 4th ed.,New York, John Wiley and Sons Inc., 1992, .387-393.
[8]. P.Sarin. J.A.Clement., V.L.Snoeyink. and W.M.Kariven., Release from corroded unlined Iron cast pipe, J. Amer.Water.Asso.,2003, 85-96
[9]. Y.Zhang.,Relative effects of water chemistry aspects of Iron corrosion, M.Sc.Thesis, State University, Virginia, 2005.
[10].M.Mhams, A.Mohamadi and S.A.Sajad, Evalution of corrosion and scaling potential of water in Rural Water supply distribution networks of Tabas,Iran,World Appl. Sci.J., 2012,17(11),1484-9.
[11].E.Hoseinzadeh, A.Yusefzadeh, N.Rahimi and Khorsandi.H., Evalution of corrosion and scaling potential of a water treatment plant, Arch.Hyg.Sci.Iran,2013,2(2),41-47.
[12]. Water-Index calculations. Marvinsilbert and Associates: Ontario, Canada, 2006.
[13]. B.Marilyn., V.Elizabeth., L. Michland. and E.Fizgerald, Cancer incidence and asbestos in drinking water , Envi.Res.,2005,244-233.
Chemistry Department, Al-Asmarya Islamic University, College of Education, Zeliten, Libya, Mobile No.+218925504107
No. of Downloads: 6 | No. of Views: 1041
Michael M. Silaev.
September 2018 - Vol 6, Issue 5
Sukwon Kim.
September 2018 - Vol 6, Issue 5
Kaoutar Hafdi, Abdelaziz Kriouile, Abderahman Kriouile.
July 2017 - Vol 5, Issue 4